3 8 .7
Ø 8
34.2
2 4 .5
5 9 .7
12 .5
3 8 .2
56.7
Ø28.4
63
4 3
14 .2
Designed to Maximum SWaP-C Advantages Cooler Weight 185 grams , 56.7mm in Length For HOT Detectors Operating at 150K-180K Uses 8mm Short Cold Finger Specially Designed to Fit Handheld Thermal Imagers Includes External Digital Temperature Controller
300
400
500
600
700
800
-50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80
150K
To ta
l C oo
lin g
Po w
er [m
W ]
Ambient Temperature [°C]
K562 Short - Cooling Power VS Ambient Temperature
2
3
4
5
6
7
100 200 300 400 500 600 700 800
150K, 23°C
150K, 71°C
Re gu
la te
d In
pu t
Po w
er [W
]
Total Heat Load [mW]
K562 Short - Regulated Input Power VS Total Heat Load
SPECIFICATIONS
K562 SHORT
Total cooling power: Cold tip temperature range: 150K-180K Temperature stability: ±0.2K
400mW@150K@71°C Product maturity: under production Meets environmental conditions per
MTTF: >17,000hr @ Basic profile Cooler weight: 185gr MIL-STD-810
Steady state input Power: Controller weight: 30gr Acoustic noise: non detectable from
(185mW@150K@23°C): 2.6Wdc typ. Input voltage: 12Vdc typ. 25m according to MIL-STD-1474E
Maximum input power: 12Wdc typ. Ambient temperature range: Service life: 15 years
Cool down time: - Operational: -40°C...+71°C Standard warranty*: 3,000hr/2 years
(150J@150K@23°C): 3.5 min. typ. - Non-Operational: -55°C...+85°C * Option to propose extended warranty
INTEGRAL ROTARY
Dimensions in mm
3 8 .7
Ø 8
34.2
2 4 .5
5 9 .7
12 .5
3 8 .2
56.7
Ø28.4
63
4 3
14 .2